<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wikido.isoftdata.com//api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Aringsmuth</id>
	<title>ISoft Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://wikido.isoftdata.com//api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Aringsmuth"/>
	<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Special:Contributions/Aringsmuth"/>
	<updated>2026-04-28T06:13:49Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.37.2</generator>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15187</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15187"/>
		<updated>2026-03-31T20:50:11Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Scanner Info */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera P172 Handheld Scanner =&lt;br /&gt;
This page will cover how to set up the Tera Android 13 Barcode Scanner PDA P172  to work with ITrack.&lt;br /&gt;
&lt;br /&gt;
The Tera scanner is the device recommended to use with ITrack.  &lt;br /&gt;
&lt;br /&gt;
== Scanner Info ==&lt;br /&gt;
The Tera Handheld scanner has a trigger button on the handle as well as a button on the side of the device.  Both buttons can be configured to scan.  &lt;br /&gt;
&lt;br /&gt;
[https://cdn.shopify.com/s/files/1/0144/3482/8374/files/TR-UMP172-2023-7-21-S26-ZQ_1.pdf?v=1689931514 Download the User Manual]&lt;br /&gt;
&lt;br /&gt;
== Setting Up a Tera Scanner ==&lt;br /&gt;
&lt;br /&gt;
From your Tera&amp;#039;s home screen, swipe up to to see apps, then select the &amp;quot;keyboardemulator&amp;quot; app.&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_keyboardemulatorapp.jpg|200px]]&lt;br /&gt;
&lt;br /&gt;
=== Function ===&lt;br /&gt;
The &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page configures whether the scanner is enabled, and manages the buttons that trigger the laser to scan.  &lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Enable Scanner&amp;#039;&amp;#039;&amp;#039; should be &amp;#039;&amp;#039;On&amp;#039;&amp;#039;.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Barcode2D&amp;#039;&amp;#039;&amp;#039; should be checked.&lt;br /&gt;
* There should be a &amp;#039;&amp;#039;&amp;#039;KeyCode&amp;#039;&amp;#039;&amp;#039; in both fields on the left.  &lt;br /&gt;
&lt;br /&gt;
If it is enabled correctly, the &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page should look like this:&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_KeyCodeCorrect.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
If the fields are empty, then pressing the button or trigger on the device won&amp;#039;t trigger the laser and no scanning will happen.&lt;br /&gt;
&lt;br /&gt;
==== If the KeyCodes are empty, follow these steps: ====&lt;br /&gt;
&lt;br /&gt;
1. Toggle &amp;quot;Enable Scanner&amp;quot; to off.&lt;br /&gt;
  [[File:Tera_ToggleOff.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
2. Tap in the KeyCode field to make the field active and put the cursor in the field.&lt;br /&gt;
  [[File:Tera_InsertKeyCode.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
3. Press the scan button on the device &amp;#039;&amp;#039;&amp;#039;-OR-&amp;#039;&amp;#039;&amp;#039; manually enter the button&amp;#039;s KeyCode. &lt;br /&gt;
&lt;br /&gt;
4. Repeat step 2 and 3 for each button you want to trigger the scan.  For the handheld scanner, you want to program both the Scan button on the right side of the device (KeyCode 139) as well as the trigger button on the handle (KeyCode 293).&lt;br /&gt;
&lt;br /&gt;
5. Toggle &amp;quot;Enable Scanner&amp;quot; back on.&lt;br /&gt;
    [[File:Tera_ToggleOn.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
=== App Settings ===&lt;br /&gt;
The &amp;#039;&amp;#039;App Settings&amp;#039;&amp;#039; page configures how the scanner communicates to apps by entering characters before and after the scanned bar code.  If these are not configured, the scanner will simply insert the bar code number as text and it won&amp;#039;t function in an automatic way.&lt;br /&gt;
&lt;br /&gt;
1. Scroll down to the &amp;#039;&amp;#039;End Mark&amp;#039;&amp;#039; section, and make sure &amp;#039;&amp;#039;&amp;#039;Enter&amp;#039;&amp;#039;&amp;#039; is checked.&lt;br /&gt;
  [[File:Tera_EndMark.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
2. In the &amp;#039;&amp;#039;Data Format&amp;#039;&amp;#039; section, insert a tilde &amp;quot;~&amp;quot; in the &amp;#039;&amp;#039;&amp;#039;Prefix&amp;#039;&amp;#039;&amp;#039; field, and leave &amp;#039;&amp;#039;&amp;#039;Suffix&amp;#039;&amp;#039;&amp;#039; blank.  The tilde ~ can be found on the symbols portion of your keyboard.&lt;br /&gt;
  [[File:Tera_DataFormat.jpg|250px]]&lt;br /&gt;
  [[File:Tera_Prefix.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;Note:&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; Some applications can configure their own overrides to the expected Preamble and End Mark.  If you modify these values manually, you need to make sure the App Settings on the device match accordingly. &lt;br /&gt;
&lt;br /&gt;
[https://itrack-chromium.scroll.site/itrack-chromium-knowledge-base/scanner-configuration Read More about configuring ITrack Chromium to work with your scanner.]&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15186</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15186"/>
		<updated>2026-03-31T20:02:47Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Setting Up a Tera Scanner */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera P172 Handheld Scanner =&lt;br /&gt;
This page will cover how to set up the Tera Android 13 Barcode Scanner PDA P172  to work with ITrack.&lt;br /&gt;
&lt;br /&gt;
The Tera scanner is the device recommended to use with ITrack.  &lt;br /&gt;
&lt;br /&gt;
== Scanner Info ==&lt;br /&gt;
The Tera Handheld scanner has a trigger button on the handle as well as a button on the side of the device.  Both buttons can be configured to scan.  &lt;br /&gt;
&lt;br /&gt;
[https://manuals.plus/wp-content/uploads/2023/11/Tera-P172-Handheld-Android-Barcode-Scanner-User-Manual.pdf Download the User Manual]&lt;br /&gt;
&lt;br /&gt;
== Setting Up a Tera Scanner ==&lt;br /&gt;
&lt;br /&gt;
From your Tera&amp;#039;s home screen, swipe up to to see apps, then select the &amp;quot;keyboardemulator&amp;quot; app.&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_keyboardemulatorapp.jpg|200px]]&lt;br /&gt;
&lt;br /&gt;
=== Function ===&lt;br /&gt;
The &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page configures whether the scanner is enabled, and manages the buttons that trigger the laser to scan.  &lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Enable Scanner&amp;#039;&amp;#039;&amp;#039; should be &amp;#039;&amp;#039;On&amp;#039;&amp;#039;.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Barcode2D&amp;#039;&amp;#039;&amp;#039; should be checked.&lt;br /&gt;
* There should be a &amp;#039;&amp;#039;&amp;#039;KeyCode&amp;#039;&amp;#039;&amp;#039; in both fields on the left.  &lt;br /&gt;
&lt;br /&gt;
If it is enabled correctly, the &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page should look like this:&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_KeyCodeCorrect.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
If the fields are empty, then pressing the button or trigger on the device won&amp;#039;t trigger the laser and no scanning will happen.&lt;br /&gt;
&lt;br /&gt;
==== If the KeyCodes are empty, follow these steps: ====&lt;br /&gt;
&lt;br /&gt;
1. Toggle &amp;quot;Enable Scanner&amp;quot; to off.&lt;br /&gt;
  [[File:Tera_ToggleOff.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
2. Tap in the KeyCode field to make the field active and put the cursor in the field.&lt;br /&gt;
  [[File:Tera_InsertKeyCode.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
3. Press the scan button on the device &amp;#039;&amp;#039;&amp;#039;-OR-&amp;#039;&amp;#039;&amp;#039; manually enter the button&amp;#039;s KeyCode. &lt;br /&gt;
&lt;br /&gt;
4. Repeat step 2 and 3 for each button you want to trigger the scan.  For the handheld scanner, you want to program both the Scan button on the right side of the device (KeyCode 139) as well as the trigger button on the handle (KeyCode 293).&lt;br /&gt;
&lt;br /&gt;
5. Toggle &amp;quot;Enable Scanner&amp;quot; back on.&lt;br /&gt;
    [[File:Tera_ToggleOn.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
=== App Settings ===&lt;br /&gt;
The &amp;#039;&amp;#039;App Settings&amp;#039;&amp;#039; page configures how the scanner communicates to apps by entering characters before and after the scanned bar code.  If these are not configured, the scanner will simply insert the bar code number as text and it won&amp;#039;t function in an automatic way.&lt;br /&gt;
&lt;br /&gt;
1. Scroll down to the &amp;#039;&amp;#039;End Mark&amp;#039;&amp;#039; section, and make sure &amp;#039;&amp;#039;&amp;#039;Enter&amp;#039;&amp;#039;&amp;#039; is checked.&lt;br /&gt;
  [[File:Tera_EndMark.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
2. In the &amp;#039;&amp;#039;Data Format&amp;#039;&amp;#039; section, insert a tilde &amp;quot;~&amp;quot; in the &amp;#039;&amp;#039;&amp;#039;Prefix&amp;#039;&amp;#039;&amp;#039; field, and leave &amp;#039;&amp;#039;&amp;#039;Suffix&amp;#039;&amp;#039;&amp;#039; blank.  The tilde ~ can be found on the symbols portion of your keyboard.&lt;br /&gt;
  [[File:Tera_DataFormat.jpg|250px]]&lt;br /&gt;
  [[File:Tera_Prefix.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;Note:&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; Some applications can configure their own overrides to the expected Preamble and End Mark.  If you modify these values manually, you need to make sure the App Settings on the device match accordingly. &lt;br /&gt;
&lt;br /&gt;
[https://itrack-chromium.scroll.site/itrack-chromium-knowledge-base/scanner-configuration Read More about configuring ITrack Chromium to work with your scanner.]&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15185</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15185"/>
		<updated>2026-03-31T20:02:36Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Setting Up a Tera Scanner */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera P172 Handheld Scanner =&lt;br /&gt;
This page will cover how to set up the Tera Android 13 Barcode Scanner PDA P172  to work with ITrack.&lt;br /&gt;
&lt;br /&gt;
The Tera scanner is the device recommended to use with ITrack.  &lt;br /&gt;
&lt;br /&gt;
== Scanner Info ==&lt;br /&gt;
The Tera Handheld scanner has a trigger button on the handle as well as a button on the side of the device.  Both buttons can be configured to scan.  &lt;br /&gt;
&lt;br /&gt;
[https://manuals.plus/wp-content/uploads/2023/11/Tera-P172-Handheld-Android-Barcode-Scanner-User-Manual.pdf Download the User Manual]&lt;br /&gt;
&lt;br /&gt;
== Setting Up a Tera Scanner ==&lt;br /&gt;
&lt;br /&gt;
From your Tera&amp;#039;s home screen, swipe up to to see apps, then select the &amp;quot;keyboardemulator&amp;quot; app.&lt;br /&gt;
[[File:Tera_keyboardemulatorapp.jpg|200px]]&lt;br /&gt;
&lt;br /&gt;
=== Function ===&lt;br /&gt;
The &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page configures whether the scanner is enabled, and manages the buttons that trigger the laser to scan.  &lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Enable Scanner&amp;#039;&amp;#039;&amp;#039; should be &amp;#039;&amp;#039;On&amp;#039;&amp;#039;.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Barcode2D&amp;#039;&amp;#039;&amp;#039; should be checked.&lt;br /&gt;
* There should be a &amp;#039;&amp;#039;&amp;#039;KeyCode&amp;#039;&amp;#039;&amp;#039; in both fields on the left.  &lt;br /&gt;
&lt;br /&gt;
If it is enabled correctly, the &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page should look like this:&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_KeyCodeCorrect.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
If the fields are empty, then pressing the button or trigger on the device won&amp;#039;t trigger the laser and no scanning will happen.&lt;br /&gt;
&lt;br /&gt;
==== If the KeyCodes are empty, follow these steps: ====&lt;br /&gt;
&lt;br /&gt;
1. Toggle &amp;quot;Enable Scanner&amp;quot; to off.&lt;br /&gt;
  [[File:Tera_ToggleOff.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
2. Tap in the KeyCode field to make the field active and put the cursor in the field.&lt;br /&gt;
  [[File:Tera_InsertKeyCode.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
3. Press the scan button on the device &amp;#039;&amp;#039;&amp;#039;-OR-&amp;#039;&amp;#039;&amp;#039; manually enter the button&amp;#039;s KeyCode. &lt;br /&gt;
&lt;br /&gt;
4. Repeat step 2 and 3 for each button you want to trigger the scan.  For the handheld scanner, you want to program both the Scan button on the right side of the device (KeyCode 139) as well as the trigger button on the handle (KeyCode 293).&lt;br /&gt;
&lt;br /&gt;
5. Toggle &amp;quot;Enable Scanner&amp;quot; back on.&lt;br /&gt;
    [[File:Tera_ToggleOn.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
=== App Settings ===&lt;br /&gt;
The &amp;#039;&amp;#039;App Settings&amp;#039;&amp;#039; page configures how the scanner communicates to apps by entering characters before and after the scanned bar code.  If these are not configured, the scanner will simply insert the bar code number as text and it won&amp;#039;t function in an automatic way.&lt;br /&gt;
&lt;br /&gt;
1. Scroll down to the &amp;#039;&amp;#039;End Mark&amp;#039;&amp;#039; section, and make sure &amp;#039;&amp;#039;&amp;#039;Enter&amp;#039;&amp;#039;&amp;#039; is checked.&lt;br /&gt;
  [[File:Tera_EndMark.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
2. In the &amp;#039;&amp;#039;Data Format&amp;#039;&amp;#039; section, insert a tilde &amp;quot;~&amp;quot; in the &amp;#039;&amp;#039;&amp;#039;Prefix&amp;#039;&amp;#039;&amp;#039; field, and leave &amp;#039;&amp;#039;&amp;#039;Suffix&amp;#039;&amp;#039;&amp;#039; blank.  The tilde ~ can be found on the symbols portion of your keyboard.&lt;br /&gt;
  [[File:Tera_DataFormat.jpg|250px]]&lt;br /&gt;
  [[File:Tera_Prefix.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;Note:&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; Some applications can configure their own overrides to the expected Preamble and End Mark.  If you modify these values manually, you need to make sure the App Settings on the device match accordingly. &lt;br /&gt;
&lt;br /&gt;
[https://itrack-chromium.scroll.site/itrack-chromium-knowledge-base/scanner-configuration Read More about configuring ITrack Chromium to work with your scanner.]&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=File:Tera_keyboardemulatorapp.jpg&amp;diff=15184</id>
		<title>File:Tera keyboardemulatorapp.jpg</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=File:Tera_keyboardemulatorapp.jpg&amp;diff=15184"/>
		<updated>2026-03-31T20:02:10Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15183</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15183"/>
		<updated>2026-03-31T20:00:51Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* App Settings */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera P172 Handheld Scanner =&lt;br /&gt;
This page will cover how to set up the Tera Android 13 Barcode Scanner PDA P172  to work with ITrack.&lt;br /&gt;
&lt;br /&gt;
The Tera scanner is the device recommended to use with ITrack.  &lt;br /&gt;
&lt;br /&gt;
== Scanner Info ==&lt;br /&gt;
The Tera Handheld scanner has a trigger button on the handle as well as a button on the side of the device.  Both buttons can be configured to scan.  &lt;br /&gt;
&lt;br /&gt;
[https://manuals.plus/wp-content/uploads/2023/11/Tera-P172-Handheld-Android-Barcode-Scanner-User-Manual.pdf Download the User Manual]&lt;br /&gt;
&lt;br /&gt;
== Setting Up a Tera Scanner ==&lt;br /&gt;
&lt;br /&gt;
From your Tera&amp;#039;s home screen, swipe up to to see apps, then select the &amp;quot;keyboardemulator&amp;quot; app.&lt;br /&gt;
&lt;br /&gt;
=== Function ===&lt;br /&gt;
The &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page configures whether the scanner is enabled, and manages the buttons that trigger the laser to scan.  &lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Enable Scanner&amp;#039;&amp;#039;&amp;#039; should be &amp;#039;&amp;#039;On&amp;#039;&amp;#039;.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Barcode2D&amp;#039;&amp;#039;&amp;#039; should be checked.&lt;br /&gt;
* There should be a &amp;#039;&amp;#039;&amp;#039;KeyCode&amp;#039;&amp;#039;&amp;#039; in both fields on the left.  &lt;br /&gt;
&lt;br /&gt;
If it is enabled correctly, the &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page should look like this:&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_KeyCodeCorrect.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
If the fields are empty, then pressing the button or trigger on the device won&amp;#039;t trigger the laser and no scanning will happen.&lt;br /&gt;
&lt;br /&gt;
==== If the KeyCodes are empty, follow these steps: ====&lt;br /&gt;
&lt;br /&gt;
1. Toggle &amp;quot;Enable Scanner&amp;quot; to off.&lt;br /&gt;
  [[File:Tera_ToggleOff.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
2. Tap in the KeyCode field to make the field active and put the cursor in the field.&lt;br /&gt;
  [[File:Tera_InsertKeyCode.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
3. Press the scan button on the device &amp;#039;&amp;#039;&amp;#039;-OR-&amp;#039;&amp;#039;&amp;#039; manually enter the button&amp;#039;s KeyCode. &lt;br /&gt;
&lt;br /&gt;
4. Repeat step 2 and 3 for each button you want to trigger the scan.  For the handheld scanner, you want to program both the Scan button on the right side of the device (KeyCode 139) as well as the trigger button on the handle (KeyCode 293).&lt;br /&gt;
&lt;br /&gt;
5. Toggle &amp;quot;Enable Scanner&amp;quot; back on.&lt;br /&gt;
    [[File:Tera_ToggleOn.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
=== App Settings ===&lt;br /&gt;
The &amp;#039;&amp;#039;App Settings&amp;#039;&amp;#039; page configures how the scanner communicates to apps by entering characters before and after the scanned bar code.  If these are not configured, the scanner will simply insert the bar code number as text and it won&amp;#039;t function in an automatic way.&lt;br /&gt;
&lt;br /&gt;
1. Scroll down to the &amp;#039;&amp;#039;End Mark&amp;#039;&amp;#039; section, and make sure &amp;#039;&amp;#039;&amp;#039;Enter&amp;#039;&amp;#039;&amp;#039; is checked.&lt;br /&gt;
  [[File:Tera_EndMark.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
2. In the &amp;#039;&amp;#039;Data Format&amp;#039;&amp;#039; section, insert a tilde &amp;quot;~&amp;quot; in the &amp;#039;&amp;#039;&amp;#039;Prefix&amp;#039;&amp;#039;&amp;#039; field, and leave &amp;#039;&amp;#039;&amp;#039;Suffix&amp;#039;&amp;#039;&amp;#039; blank.  The tilde ~ can be found on the symbols portion of your keyboard.&lt;br /&gt;
  [[File:Tera_DataFormat.jpg|250px]]&lt;br /&gt;
  [[File:Tera_Prefix.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;Note:&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; Some applications can configure their own overrides to the expected Preamble and End Mark.  If you modify these values manually, you need to make sure the App Settings on the device match accordingly. &lt;br /&gt;
&lt;br /&gt;
[https://itrack-chromium.scroll.site/itrack-chromium-knowledge-base/scanner-configuration Read More about configuring ITrack Chromium to work with your scanner.]&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=File:Tera_Prefix.jpg&amp;diff=15182</id>
		<title>File:Tera Prefix.jpg</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=File:Tera_Prefix.jpg&amp;diff=15182"/>
		<updated>2026-03-31T20:00:04Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=File:Tera_DataFormat.jpg&amp;diff=15181</id>
		<title>File:Tera DataFormat.jpg</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=File:Tera_DataFormat.jpg&amp;diff=15181"/>
		<updated>2026-03-31T19:58:59Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=File:Tera_EndMark.jpg&amp;diff=15180</id>
		<title>File:Tera EndMark.jpg</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=File:Tera_EndMark.jpg&amp;diff=15180"/>
		<updated>2026-03-31T19:57:58Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15179</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15179"/>
		<updated>2026-03-31T19:51:30Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Setting Up a Tera Scanner */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera P172 Handheld Scanner =&lt;br /&gt;
This page will cover how to set up the Tera Android 13 Barcode Scanner PDA P172  to work with ITrack.&lt;br /&gt;
&lt;br /&gt;
The Tera scanner is the device recommended to use with ITrack.  &lt;br /&gt;
&lt;br /&gt;
== Scanner Info ==&lt;br /&gt;
The Tera Handheld scanner has a trigger button on the handle as well as a button on the side of the device.  Both buttons can be configured to scan.  &lt;br /&gt;
&lt;br /&gt;
[https://manuals.plus/wp-content/uploads/2023/11/Tera-P172-Handheld-Android-Barcode-Scanner-User-Manual.pdf Download the User Manual]&lt;br /&gt;
&lt;br /&gt;
== Setting Up a Tera Scanner ==&lt;br /&gt;
&lt;br /&gt;
From your Tera&amp;#039;s home screen, swipe up to to see apps, then select the &amp;quot;keyboardemulator&amp;quot; app.&lt;br /&gt;
&lt;br /&gt;
=== Function ===&lt;br /&gt;
The &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page configures whether the scanner is enabled, and manages the buttons that trigger the laser to scan.  &lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Enable Scanner&amp;#039;&amp;#039;&amp;#039; should be &amp;#039;&amp;#039;On&amp;#039;&amp;#039;.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Barcode2D&amp;#039;&amp;#039;&amp;#039; should be checked.&lt;br /&gt;
* There should be a &amp;#039;&amp;#039;&amp;#039;KeyCode&amp;#039;&amp;#039;&amp;#039; in both fields on the left.  &lt;br /&gt;
&lt;br /&gt;
If it is enabled correctly, the &amp;#039;&amp;#039;Function&amp;#039;&amp;#039; page should look like this:&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_KeyCodeCorrect.jpg|250px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
If the fields are empty, then pressing the button or trigger on the device won&amp;#039;t trigger the laser and no scanning will happen.&lt;br /&gt;
&lt;br /&gt;
==== If the KeyCodes are empty, follow these steps: ====&lt;br /&gt;
&lt;br /&gt;
1. Toggle &amp;quot;Enable Scanner&amp;quot; to off.&lt;br /&gt;
  [[File:Tera_ToggleOff.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
2. Tap in the KeyCode field to make the field active and put the cursor in the field.&lt;br /&gt;
  [[File:Tera_InsertKeyCode.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
3. Press the scan button on the device &amp;#039;&amp;#039;&amp;#039;-OR-&amp;#039;&amp;#039;&amp;#039; manually enter the button&amp;#039;s KeyCode. &lt;br /&gt;
&lt;br /&gt;
4. Repeat step 2 and 3 for each button you want to trigger the scan.  For the handheld scanner, you want to program both the Scan button on the right side of the device (KeyCode 139) as well as the trigger button on the handle (KeyCode 293).&lt;br /&gt;
&lt;br /&gt;
5. Toggle &amp;quot;Enable Scanner&amp;quot; back on.&lt;br /&gt;
    [[File:Tera_ToggleOn.jpg|150px]]&lt;br /&gt;
&lt;br /&gt;
=== App Settings ===&lt;br /&gt;
The App Settings page configures how the scanner communicates to apps by entering characters before and after the scanned bar code.  If these are not configured, the scanner will simply insert the bar code number as text and it won&amp;#039;t function in an automatic way.&lt;br /&gt;
&lt;br /&gt;
1. Scroll down to the End Mark section, and make sure &amp;quot;Enter&amp;quot; is enabled for the end mark.&lt;br /&gt;
&lt;br /&gt;
2. In the Data Format section, insert a tilde &amp;quot;~&amp;quot; in the Prefix field, and leave Suffix blank.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;Note:&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; Some applications can configure their own overrides to the expected Preamble and End Mark.  If you modify these values manually, you need to make sure the App Settings on the device match accordingly. &lt;br /&gt;
&lt;br /&gt;
[https://itrack-chromium.scroll.site/itrack-chromium-knowledge-base/scanner-configuration Read More about configuring ITrack Chromium to work with your scanner.]&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=File:Tera_ToggleOn.jpg&amp;diff=15178</id>
		<title>File:Tera ToggleOn.jpg</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=File:Tera_ToggleOn.jpg&amp;diff=15178"/>
		<updated>2026-03-31T19:49:15Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=File:Tera_InsertKeyCode.jpg&amp;diff=15177</id>
		<title>File:Tera InsertKeyCode.jpg</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=File:Tera_InsertKeyCode.jpg&amp;diff=15177"/>
		<updated>2026-03-31T19:44:48Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=File:Tera_ToggleOff.jpg&amp;diff=15176</id>
		<title>File:Tera ToggleOff.jpg</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=File:Tera_ToggleOff.jpg&amp;diff=15176"/>
		<updated>2026-03-31T19:41:18Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=File:Tera_KeyCodeCorrect.jpg&amp;diff=15175</id>
		<title>File:Tera KeyCodeCorrect.jpg</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=File:Tera_KeyCodeCorrect.jpg&amp;diff=15175"/>
		<updated>2026-03-31T19:11:39Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15174</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15174"/>
		<updated>2026-03-31T18:48:09Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Tera Scanners */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera P172 Handheld Scanner =&lt;br /&gt;
This page will cover how to set up the Tera Android 13 Barcode Scanner PDA P172  to work with ITrack.&lt;br /&gt;
&lt;br /&gt;
The Tera scanner is the device recommended to use with ITrack.  &lt;br /&gt;
&lt;br /&gt;
== Scanner Info ==&lt;br /&gt;
The Tera Handheld scanner has a trigger button on the handle as well as a button on the side of the device.  Both buttons can be configured to scan.  &lt;br /&gt;
&lt;br /&gt;
[https://manuals.plus/wp-content/uploads/2023/11/Tera-P172-Handheld-Android-Barcode-Scanner-User-Manual.pdf Download the User Manual]&lt;br /&gt;
&lt;br /&gt;
== Setting Up a Tera Scanner ==&lt;br /&gt;
&lt;br /&gt;
From your Tera&amp;#039;s home screen, swipe up to to see apps, then select the &amp;quot;keyboardemulator&amp;quot; app.&lt;br /&gt;
&lt;br /&gt;
=== Function ===&lt;br /&gt;
The Function page configures whether the scanner is enabled, and manages the buttons that trigger the laser to scan.  &lt;br /&gt;
&lt;br /&gt;
Barcode2D should be enabled, and there should be a KeyCode in both fields on the left.  If it is enabled correctly, the Function page should look like this:&lt;br /&gt;
&lt;br /&gt;
If the fields are empty, then pressing the button or trigger on the device won&amp;#039;t trigger the laser and no scanning will happen.&lt;br /&gt;
&lt;br /&gt;
==== If the KeyCodes are empty, follow these steps: ====&lt;br /&gt;
&lt;br /&gt;
1. Toggle &amp;quot;Enable Scanner&amp;quot; to off.&lt;br /&gt;
2. Tap in the KeyCode field to make the field active and put the cursor in the field.&lt;br /&gt;
3. Press the scan button on the device ```-OR-``` manually enter the button&amp;#039;s KeyCode. &lt;br /&gt;
4. Repeat step 2 and 3 for each button you want to trigger the scan.  For the handheld scanner, you want to program both the Scan button on the right side of the device (KeyCode 139) as well as the trigger button on the handle (KeyCode 293).&lt;br /&gt;
5. Toggle &amp;quot;Enable Scanner&amp;quot; back on.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_config.png|200px]]&lt;br /&gt;
&lt;br /&gt;
=== App Settings ===&lt;br /&gt;
The App Settings page configures how the scanner communicates to apps by entering characters before and after the scanned bar code.  If these are not configured, the scanner will simply insert the bar code number as text and it won&amp;#039;t function in an automatic way.&lt;br /&gt;
&lt;br /&gt;
1. Scroll down to the End Mark section, and make sure &amp;quot;Enter&amp;quot; is enabled for the end mark.&lt;br /&gt;
&lt;br /&gt;
2. In the Data Format section, insert a tilde &amp;quot;~&amp;quot; in the Prefix field, and leave Suffix blank.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
*Note: Some applications can configure their own overrides to the expected Preamble and End Mark.  If you modify these values manually, you need to make sure the App Settings on the device match accordingly. &lt;br /&gt;
&lt;br /&gt;
[https://itrack-chromium.scroll.site/itrack-chromium-knowledge-base/scanner-configuration Read More about configuring ITrack Chromium to work with your scanner.]&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15173</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15173"/>
		<updated>2026-03-31T16:24:57Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Tera Handheld Scanner */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera Scanners =&lt;br /&gt;
The Tera scanner is the device recommended to use with ITrack.  Tera makes a range of scanners, but the recommended devices are the Tera Android 13 Barcode Scanner PDA P172 handheld scanner, or the rugged Windows tablet.&lt;br /&gt;
&lt;br /&gt;
== Tera Handheld Scanner ==&lt;br /&gt;
The Tera Android 13 Barcode Scanner PDA P172 has a handheld trigger scanner as well as a button on the side of the device.  Both buttons can be configured to scan.  &lt;br /&gt;
&lt;br /&gt;
[https://manuals.plus/wp-content/uploads/2023/11/Tera-P172-Handheld-Android-Barcode-Scanner-User-Manual.pdf Download the User Manual]&lt;br /&gt;
&lt;br /&gt;
[[File:Tera_config.png|200px]]&lt;br /&gt;
&lt;br /&gt;
To enable the trigger on the Tera scanner handle:&lt;br /&gt;
&lt;br /&gt;
1. Get to the Scanner Config Page. &lt;br /&gt;
&lt;br /&gt;
2. Disable the scanner.&lt;br /&gt;
&lt;br /&gt;
3. Key in 293 on the scanner keypad.&lt;br /&gt;
&lt;br /&gt;
4. Re-enable the scanner.&lt;br /&gt;
&lt;br /&gt;
5. The scanner config page should look like the image above if it&amp;#039;s set correctly.&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15172</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15172"/>
		<updated>2026-03-31T15:47:39Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Tera Scanner */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera Handheld Scanner =&lt;br /&gt;
Tera is the main product that we sell to customers.  They can get a handheld android scanner or a rugged windows tablet. &lt;br /&gt;
&lt;br /&gt;
[[File:Tera_config.png|200px]]&lt;br /&gt;
&lt;br /&gt;
To enable the trigger on the Tera scanner handle:&lt;br /&gt;
&lt;br /&gt;
1. Get to the Scanner Config Page. &lt;br /&gt;
&lt;br /&gt;
2. Disable the scanner.&lt;br /&gt;
&lt;br /&gt;
3. Key in 293 on the scanner keypad.&lt;br /&gt;
&lt;br /&gt;
4. Re-enable the scanner.&lt;br /&gt;
&lt;br /&gt;
5. The scanner config page should look like the image above if it&amp;#039;s set correctly.&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15171</id>
		<title>Configuring a barcode scanner</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Configuring_a_barcode_scanner&amp;diff=15171"/>
		<updated>2026-03-31T15:46:25Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
&lt;br /&gt;
= Tera Scanner =&lt;br /&gt;
[[File:Tera_config.png|200px]]&lt;br /&gt;
&lt;br /&gt;
To enable the trigger on the Tera scanner handle:&lt;br /&gt;
&lt;br /&gt;
1. Get to the Scanner Config Page. &lt;br /&gt;
&lt;br /&gt;
2. Disable the scanner.&lt;br /&gt;
&lt;br /&gt;
3. Key in 293 on the scanner keypad.&lt;br /&gt;
&lt;br /&gt;
4. Re-enable the scanner.&lt;br /&gt;
&lt;br /&gt;
5. The scanner config page should look like the image above if it&amp;#039;s set correctly.&lt;br /&gt;
&lt;br /&gt;
== Windows 11 Industrial Rugged Tablet ==&lt;br /&gt;
Two additional applications are required to use the scanner features: Honeywell Download manager tool (which will manage any subsequent Honeywell software downloads), then an EZConfig for Scanning software for the configuration of scanner itself. Both parts can be downloaded from the same portal: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the zip file containing the Honeywell Download manager tool, select &amp;quot;here&amp;quot; marked by the first arrow. When finished, right-click the zip file selecting &amp;quot;Extract all...&amp;quot; then select a home/path for this installer.&lt;br /&gt;
&lt;br /&gt;
To download the EZConfig for Scanning, in the file system on the left: Software -&amp;gt; Barcode Scanner -&amp;gt; Software -&amp;gt; Tools and Utilities -&amp;gt; EZConfig for Scanning -&amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Open the EZConfig for Scanning software when it&amp;#039;s finished downloading. &lt;br /&gt;
# Open the file &amp;quot;EZConfig-Scanning v4_msedge&amp;quot;&lt;br /&gt;
# select &amp;quot;Connected Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Configure Device&amp;quot;&lt;br /&gt;
# select &amp;quot;Data Formatting&amp;quot;&lt;br /&gt;
# in Data Formatting, verify that you are on the &amp;quot;Prefix/Suffix&amp;quot; tab&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
&lt;br /&gt;
This may be out-dated. &lt;br /&gt;
&lt;br /&gt;
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^&lt;br /&gt;
&lt;br /&gt;
Instead of using EZConfig, we need to use another Honeywell tool named SoftWedge. It can be downloaded from the same link as the download manager and EZConfig: https://hsmftp.honeywell.com/&lt;br /&gt;
&lt;br /&gt;
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software &amp;gt; Barcode Scanners &amp;gt; Software &amp;gt; Tools and Utilities &amp;gt; Softwedge &amp;gt; Current.&lt;br /&gt;
&lt;br /&gt;
# Unzip the SoftWedge folder&lt;br /&gt;
# Open and read the PDF instructions in the folder&lt;br /&gt;
# Run SoftWedge.exe, it will pop up in the system tray&lt;br /&gt;
# Open up SoftWedge and verify the &amp;quot;port status&amp;quot; is connected&lt;br /&gt;
# enter &amp;lt;code&amp;gt;~&amp;lt;/code&amp;gt; as the Prefix&lt;br /&gt;
# enter &amp;lt;code&amp;gt;{  CR}&amp;lt;/code&amp;gt; as the Suffix&lt;br /&gt;
# Verify things are working by doing test scans in Chromium/EEweb Configuration-&amp;gt;Scanner-&amp;gt;Test Scanner&lt;br /&gt;
&lt;br /&gt;
== NOTE on ENTERPRISE LX setup ==&lt;br /&gt;
enterpise lx  default pre/postable&lt;br /&gt;
preamble = &amp;quot;126&amp;quot;    = &amp;quot;~&amp;quot;&lt;br /&gt;
postamble = &amp;quot;13&amp;quot; = &amp;quot;Enter&amp;quot;&lt;br /&gt;
 &lt;br /&gt;
For munbyn scanner,   the postamble/suffix  does not allow you to use &amp;quot;Enter&amp;quot;  so you need to leave that blank and instead check the box under EndMark  that says &amp;quot;Enter&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== TROUBLESHOOTING ==&lt;br /&gt;
My Tera scan returns a different barcode every time despite scanning the same barcode!&lt;br /&gt;
&lt;br /&gt;
# At the top of the LX Landing Page where it say Signed In / Not Signed In, tap the Sign-In and choose &amp;quot;Disable Honeywell Mode.&amp;quot;&lt;br /&gt;
&lt;br /&gt;
=Zebra DS2278=&lt;br /&gt;
&lt;br /&gt;
This page will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with iSoft products on mobile devices.&lt;br /&gt;
&lt;br /&gt;
==Scanner Info==&lt;br /&gt;
* Approx Cost: $190-$280 depending on accessories and support&lt;br /&gt;
* Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows&lt;br /&gt;
&lt;br /&gt;
==Quick Start Guide==&lt;br /&gt;
===Android using Chrome===&lt;br /&gt;
* The fastest way to get started is to scan the appropriate barcode for your device type. **Make sure your device is fully charged!&lt;br /&gt;
* This model of scanner can scan from a high resolution monitor or screen &lt;br /&gt;
* Each of the barcodes below will change the defaults on your scanner.  You will need to &amp;quot;forget&amp;quot; or &amp;quot;remove&amp;quot; the device in your Bluetooth settings and reconnect&lt;br /&gt;
* The below barcodes have the following settings: &amp;#039;&amp;#039;&amp;#039;Prefix : Suffix $&amp;#039;&amp;#039;&amp;#039;, HID features for iOS, Host: HID BT Classic&lt;br /&gt;
[[Image:AndroidBarcode.JPG]]&lt;br /&gt;
&lt;br /&gt;
===iOS using ITrack LX App===&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Tip: You do not need to set up this device as a keyboard wedge&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
1. You first need to install the Zebra iOS app https://apps.apple.com/us/app/zebra-scanner-control/id1034012069&lt;br /&gt;
&lt;br /&gt;
2. Open that app and go to Connection Help &amp;gt; Pair DS2278&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-setup-barcodes.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
3. Follow the onscreen instructions&lt;br /&gt;
&lt;br /&gt;
4. Go back to the main screen and choose Connect&lt;br /&gt;
&lt;br /&gt;
5. Tap on the DS2278 and choose Disconnect(this will disconnect it from the Zebra app so we can connect it to the ITrack LX app)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra-DS2278-disconnect-screen.PNG|400px]]&lt;br /&gt;
&lt;br /&gt;
6. Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.&lt;br /&gt;
&lt;br /&gt;
==Charging the Scanner==&lt;br /&gt;
* The charging circuit on the scanner is capable of using as much current as possible based on the power source&lt;br /&gt;
* Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA)&lt;br /&gt;
&lt;br /&gt;
[[Image:Zebra_battery.JPG]]&lt;br /&gt;
&lt;br /&gt;
==123Scan Software==&lt;br /&gt;
&lt;br /&gt;
==Explanation of Settings==&lt;br /&gt;
&lt;br /&gt;
==External Links==&lt;br /&gt;
* Zebra Support Page [https://www.zebra.com/us/en/support-downloads/scanners/general-purpose-scanners/ds2200-series.html link]&lt;br /&gt;
* 123Scan Software Download [https://www.zebra.com/us/en/products/software/scanning-systems/123scan.html link]&lt;br /&gt;
* Full Manual Download [https://www.zebra.com/content/dam/zebra_new_ia/en-us/manuals/barcode-scanners/ds2278-prg-en.pdf link]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=Honeywell=&lt;br /&gt;
&lt;br /&gt;
== Compatibility Notes ==&lt;br /&gt;
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18&lt;br /&gt;
&lt;br /&gt;
== Setting up a Honeywell Scanner ==&lt;br /&gt;
ScanPal EDA71  &lt;br /&gt;
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71&lt;br /&gt;
&lt;br /&gt;
These are the screens you set through to set up the honeywell device&lt;br /&gt;
&lt;br /&gt;
Settings -&amp;gt; Honeywell Settings -&amp;gt; Scan Settings -&amp;gt; Internal Scanner -&amp;gt; Default profile -&amp;gt; Data Processing Settings&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Wedge = checked&lt;br /&gt;
&lt;br /&gt;
Wedge Method = Keyboard&lt;br /&gt;
&lt;br /&gt;
no Prefix&lt;br /&gt;
&lt;br /&gt;
no Suffix&lt;br /&gt;
&lt;br /&gt;
Wedge as keys = empty input&lt;br /&gt;
&lt;br /&gt;
[[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Enterprise LX Honeywell config info ==&lt;br /&gt;
&lt;br /&gt;
A global database setting &amp;quot;Scanner Mode (ambleMode,honeywell)&amp;quot; needs to be set to &amp;quot;honeywell&amp;quot;&lt;br /&gt;
&lt;br /&gt;
The current default is ambleMode which may change in the near future.&lt;br /&gt;
The following query will let you check on the setting.   Note: A user has to have logged into an lx app before the default settings are present. &lt;br /&gt;
&lt;br /&gt;
&amp;lt;syntaxhighlight lang=&amp;quot;sql&amp;quot;&amp;gt;&lt;br /&gt;
SELECT&lt;br /&gt;
   `globalsettingvalue`.`settingid`&lt;br /&gt;
    , `setting`.`location`&lt;br /&gt;
    , `setting`.`name`&lt;br /&gt;
    , `globalsettingvalue`.`value`&lt;br /&gt;
    , `setting`.`defaultvalue`&lt;br /&gt;
    , `setting`.`scope`&lt;br /&gt;
    , `setting`.`settingtype`&lt;br /&gt;
    , `value`=`defaultvalue` AS isdefault&lt;br /&gt;
FROM&lt;br /&gt;
    `globalsettingvalue`&lt;br /&gt;
    INNER JOIN `setting` &lt;br /&gt;
        ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)&lt;br /&gt;
WHERE (`setting`.`name` = &amp;#039;Scanner Mode (ambleMode,honeywell)&amp;#039;);&lt;br /&gt;
&amp;lt;/syntaxhighlight&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=Munbyn=&lt;br /&gt;
&lt;br /&gt;
== Setting up a Munbyn Scanner ==&lt;br /&gt;
This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/&amp;lt;br&amp;gt;&lt;br /&gt;
To set up:&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Swipe up to see apps, then tap on &amp;quot;keyboardemulator&amp;quot;.&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;Function&amp;quot; page, make sure &amp;quot;Enable Scanner&amp;quot; is on.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner1.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
On the &amp;quot;AppSettings&amp;quot; page, turn on &amp;quot;Release key off scan&amp;quot; (if it is not already enabled).&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner2.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Then scroll down to &amp;quot;Process mode&amp;quot;. Make sure it is set to &amp;quot;keyboard input&amp;quot;. Under &amp;quot;End mark&amp;quot;, none of the options should be checked.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner3.png|200px]]&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
Prefix/preamble and suffix/postamble for the device can be edited under &amp;quot;Data Format&amp;quot;. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.&amp;lt;br&amp;gt;&lt;br /&gt;
[[File:scanner4.png|200px]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15170</id>
		<title>Scanners</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15170"/>
		<updated>2026-03-31T15:45:33Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Barcode Scanner Resources */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Barcode Scanner Resources=&lt;br /&gt;
&lt;br /&gt;
Pages related to or about scanners/scanning.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Devices ==&lt;br /&gt;
* [[Configuring a barcode scanner]]&lt;br /&gt;
&lt;br /&gt;
== ITrack ==&lt;br /&gt;
* [[ITrack/Barcodes]]&lt;br /&gt;
&lt;br /&gt;
== Presage ==&lt;br /&gt;
* [[Presage/Recent Application Changes]] (some mentions of scanners)&lt;br /&gt;
* [[Presage/Scanner]]&lt;br /&gt;
* [[Presage/User Guide/How to:]] (49-53 are scanner related)&lt;br /&gt;
* [[Presage/User Guide/ITrackLX Mobile App]]&lt;br /&gt;
&lt;br /&gt;
== Outdated Documents ==&lt;br /&gt;
* [[Setting Up the MC-3100]]&lt;br /&gt;
* [[LX Scanning on an Android Device]]&lt;br /&gt;
* [[Ordering ITrack LX Bar Code Scanner]]&lt;br /&gt;
* [[ITrack/Chromium Scanner Page]]&lt;br /&gt;
* [[ITrack Pro LX/VIN Decoding]]&lt;br /&gt;
* [[ITrack LX support]]&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15169</id>
		<title>Scanners</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15169"/>
		<updated>2026-03-31T15:44:53Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Barcode Scanner Resources */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Barcode Scanner Resources=&lt;br /&gt;
&lt;br /&gt;
Pages related to or about scanners/scanning.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Devices ==&lt;br /&gt;
* [[Configuring_a_barcode_scanner]]&lt;br /&gt;
&lt;br /&gt;
== ITrack ==&lt;br /&gt;
* [[ITrack/Barcodes]]&lt;br /&gt;
* [[ITrack LX support]]&lt;br /&gt;
&lt;br /&gt;
== Presage ==&lt;br /&gt;
* [[Presage/Recent Application Changes]] (some mentions of scanners)&lt;br /&gt;
* [[Presage/Scanner]]&lt;br /&gt;
* [[Presage/User Guide/How to:]] (49-53 are scanner related)&lt;br /&gt;
* [[Presage/User Guide/ITrackLX Mobile App]]&lt;br /&gt;
&lt;br /&gt;
== Outdated Documents ==&lt;br /&gt;
* [[Setting Up the MC-3100]]&lt;br /&gt;
* [[LX Scanning on an Android Device]]&lt;br /&gt;
* [[Ordering ITrack LX Bar Code Scanner]]&lt;br /&gt;
* [[ITrack/Chromium Scanner Page]]&lt;br /&gt;
* [[ITrack Pro LX/VIN Decoding]]&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15168</id>
		<title>Scanners</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15168"/>
		<updated>2026-03-31T15:44:16Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Barcode Scanner Resources */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Barcode Scanner Resources=&lt;br /&gt;
&lt;br /&gt;
Pages related to or about scanners/scanning.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Devices ==&lt;br /&gt;
* [[Configuring_a_barcode_scanner]]&lt;br /&gt;
&lt;br /&gt;
== ITrack ==&lt;br /&gt;
* [[ITrack/Barcodes]]&lt;br /&gt;
* [[ITrack LX support]]&lt;br /&gt;
* [[ITrack Pro LX/VIN Decoding]]&lt;br /&gt;
&lt;br /&gt;
== Presage ==&lt;br /&gt;
* [[Presage/Recent Application Changes]] (some mentions of scanners)&lt;br /&gt;
* [[Presage/Scanner]]&lt;br /&gt;
* [[Presage/User Guide/How to:]] (49-53 are scanner related)&lt;br /&gt;
* [[Presage/User Guide/ITrackLX Mobile App]]&lt;br /&gt;
&lt;br /&gt;
== Outdated Documents ==&lt;br /&gt;
* [[Setting Up the MC-3100]]&lt;br /&gt;
* [[LX Scanning on an Android Device]]&lt;br /&gt;
* [[Ordering ITrack LX Bar Code Scanner]]&lt;br /&gt;
* [[ITrack/Chromium Scanner Page]]&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15167</id>
		<title>Scanners</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15167"/>
		<updated>2026-03-31T15:43:03Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* ITrack */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Barcode Scanner Resources=&lt;br /&gt;
&lt;br /&gt;
Pages related to or about scanners/scanning.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Devices ==&lt;br /&gt;
* [[Honeywell Scanner]]&lt;br /&gt;
* [[Munbyn Scanner]]&lt;br /&gt;
* [[Zebra DS2278 Scanner]]&lt;br /&gt;
&lt;br /&gt;
== ITrack ==&lt;br /&gt;
* [[ITrack/Barcodes]]&lt;br /&gt;
* [[ITrack/Chromium Scanner Page]]&lt;br /&gt;
* [[ITrack LX support]]&lt;br /&gt;
* [[ITrack Pro LX/VIN Decoding]]&lt;br /&gt;
* [[Ordering ITrack LX Bar Code Scanner]]&lt;br /&gt;
&lt;br /&gt;
== Presage ==&lt;br /&gt;
* [[Presage/Recent Application Changes]] (some mentions of scanners)&lt;br /&gt;
* [[Presage/Scanner]]&lt;br /&gt;
* [[Presage/User Guide/How to:]] (49-53 are scanner related)&lt;br /&gt;
* [[Presage/User Guide/ITrackLX Mobile App]]&lt;br /&gt;
&lt;br /&gt;
== Outdated Documents ==&lt;br /&gt;
* [[Setting Up the MC-3100]]&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15166</id>
		<title>Scanners</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15166"/>
		<updated>2026-03-31T15:42:27Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Barcode Scanner Resources */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Barcode Scanner Resources=&lt;br /&gt;
&lt;br /&gt;
Pages related to or about scanners/scanning.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Devices ==&lt;br /&gt;
* [[Honeywell Scanner]]&lt;br /&gt;
* [[Munbyn Scanner]]&lt;br /&gt;
* [[Zebra DS2278 Scanner]]&lt;br /&gt;
&lt;br /&gt;
== ITrack ==&lt;br /&gt;
* [[ITrack/Barcodes]]&lt;br /&gt;
* [[ITrack/Chromium Scanner Page]]&lt;br /&gt;
* [[ITrack LX support]]&lt;br /&gt;
* [[ITrack Pro LX/VIN Decoding]]&lt;br /&gt;
* [[LX Scanning on an Android Device]]&lt;br /&gt;
* [[Ordering ITrack LX Bar Code Scanner]]&lt;br /&gt;
&lt;br /&gt;
== Presage ==&lt;br /&gt;
* [[Presage/Recent Application Changes]] (some mentions of scanners)&lt;br /&gt;
* [[Presage/Scanner]]&lt;br /&gt;
* [[Presage/User Guide/How to:]] (49-53 are scanner related)&lt;br /&gt;
* [[Presage/User Guide/ITrackLX Mobile App]]&lt;br /&gt;
&lt;br /&gt;
== Outdated Documents ==&lt;br /&gt;
* [[Setting Up the MC-3100]]&lt;/div&gt;</summary>
		<author><name>Aringsmuth</name></author>
	</entry>
	<entry>
		<id>https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15165</id>
		<title>Scanners</title>
		<link rel="alternate" type="text/html" href="https://wikido.isoftdata.com//index.php?title=Scanners&amp;diff=15165"/>
		<updated>2026-03-31T15:42:06Z</updated>

		<summary type="html">&lt;p&gt;Aringsmuth: /* Devices */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;=Barcode Scanner Resources=&lt;br /&gt;
&lt;br /&gt;
Pages related to or about scanners/scanning.&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Devices ==&lt;br /&gt;
* [[Honeywell Scanner]]&lt;br /&gt;
* [[Munbyn Scanner]]&lt;br /&gt;
* [[Zebra DS2278 Scanner]]&lt;br /&gt;
&lt;br /&gt;
== ITrack ==&lt;br /&gt;
* [[ITrack/Barcodes]]&lt;br /&gt;
* [[ITrack/Chromium Scanner Page]]&lt;br /&gt;
* [[ITrack LX support]]&lt;br /&gt;
* [[ITrack Pro LX/VIN Decoding]]&lt;br /&gt;
* [[LX Scanning on an Android Device]]&lt;br /&gt;
* [[Ordering ITrack LX Bar Code Scanner]]&lt;br /&gt;
&lt;br /&gt;
== Presage ==&lt;br /&gt;
* [[Presage/Recent Application Changes]] (some mentions of scanners)&lt;br /&gt;
* [[Presage/Scanner]]&lt;br /&gt;
* [[Presage/User Guide/How to:]] (49-53 are scanner related)&lt;br /&gt;