* reportparameter - a table in the database that associates parameters to reports | * reportparameter - a table in the database that associates parameters to reports | ||
== FAQ == | |||
== Common Errors (Table Mode)== | === How does the web report viewer work? === | ||
Since we can't run crystal reports directly in the browser, we need to run them on a central server and send them back to the web browser. There are multiple servers involved in this process, which I'll outline below | |||
* The report and parameter list are loaded from the application's API (Chromium, Presage API, EE API) | |||
* The user selects a report, fills out parameters, and clicks "Preview" | |||
* A request is sent to the application backend (Chromium, Presage API, EE API) | |||
* Application backend sends a request to Crystal Server, running on Bunnahabhain, or a customer server if relevant. This requests includes details of the report to run, which database to run it on, and a valid session token for that database. | |||
* Bunnahabhain takes this request, and attempts to validate the given session token in the given database. If this fails, such as if the token is invalid or it can't connect to the database, an "Invalid Session" error is thrown. | |||
* After the session is validated, Crystal Server will download the report file from the customer's database, and run default parameter queries. The report is saved to the "cache directory" specified in the config, with the file's hash as the file name. | |||
* Then, Crystal Server creates a command line string to run Report Commander for the given report and parameters | |||
* Report Commander is then invoked to generate the PDF, connecting to the database with ODBC. The PDF is saved to a folder in the Crystal Server's "cache directory". If Report Commander throws an error, it is forwarded to the application API (Chromium, Presage API, EE API), which saves it to the <code>reportqueue</code> table and forwards that error to the client, where it is displayed. | |||
* If it succeeds, the report file is base64 encoded and sent back to the application API (Chromium, Presage API, EE API), along with the time it took to execute the report. | |||
* The application API receives the request, saves the details to <code>reportqueue</code>/<code>reportqueueparameter</code>, and returns the base64 encoded PDF to the client | |||
* The client receives the response from its backend, and displays the base64 encoded PDF in the browser using an <code><object/></code> tag | |||
==== How is that different from desktop? ==== | |||
ITrack desktop talks directly to the Crystal Reports SDK on the individual workstation, instead of sending report jobs to a central server (Bunnahabhain) running Crystal Server. Crystal Server then uses Report Commander to create the PDF. | |||
=== What is handled by Crystal Server and what is handled by Report Queue? === | |||
Report Queue and Crystal Server are two separate systems that do not interact, so it's important to understand the boundaries between them. | |||
Crystal Server generates PDFs that can be viewed in a web browser. Crystal Server only generates the PDF, but it's typically displayed in either the "Report Viewer" screen, or in the "Send Report" modal in the application that requested it. | |||
Report Queue handles emailing and printing of reports. In the web, you can print/email using Report Queue by selecting "Printer" or "Email" in the "Send Report" modal. | |||
=== Can Crystal Server (web report viewer) generate PDFs of different sizes? === | |||
Unfortunately not. Report PDFs created by Crystal Server are always letter size. Note that this only applies to report previews; if the customer has a Report Queue instance they can email or print a report of a different size that way. | |||
=== Why can't web work the same way as desktop? === | |||
Chromium, Presage Web, and Enterprise Web run inside of a web browser, and can therefore be used on multiple operating systems without installing anything. Crystal Reports SDK is Windows-only and requires installation. Therefore, we need a central server to generate the pdf and send it back to the web browser (with some extra steps in between) | |||
=== Why does this report run on desktop, but not on web? === | |||
As outlined above, web and desktop have entirely different stacks for running crystal reports. In short, web uses Report Commander instead of the Crystal SDK. I don't know exactly how the official Crystal SDK works, but it seems to be more tolerant to being passed extra parameters, or missing parameters. Report Commander is pickier so it will throw when you give it an extra parameter not found in the report, or if you are missing a required parameter value. As a result, basically every error in this Wiki article is web-exclusive. | |||
=== Why aren't reports updated automatically in the web? === | |||
Report updates were historically done by ITrack/Presage desktop, and there is currently no system for automatically updating reports without using desktop. One is in progress, but as of 2/4/2026, it is not ready for primetime. | |||
=== Why do I sometimes get "504 Gateway Timeout" when running a report in web? === | |||
As outlined above, there are multiple web servers involved in the process of generating a PDF from a Crystal Report in the web, and each one of them has their own server-level timeouts. The web server(s) connecting you to the application API (Chromium, Presage API, EE API) might time you out, and so might the web server connecting the application API to the Crystal Server. | |||
The NGINX default timeout is 60 seconds, and it's expected that some reports will take longer than this. More on this later. | |||
Presage Web has set its internal NGINX <code>proxy_read_timeout</code> for <code>/graphql</code> to <code>300s</code>, meaning that any and all requests to the API will time out at 300s instead of the default of 60s. However, the VM-level NGINX also defaults <code>proxy_read_timeout</code> to <code>60s</code> and if that's not raised, then the VM-level NGINX will time out before the Web-level NGINX hits its timeout. | |||
Currently EE API uses the default <code>proxy_read_timeout</code> of <code>60s</code>. | |||
I do not know what timeouts are at play for Chromium since it uses a socket server instead of a GraphQL server like Presage Web and EEW do. | |||
Requests to Crystal Server on Bunnahabhain currently time out at 4m, so provided that the web client -> API timeout is longer than that (such as 5m), the API can catch the timeout error and return a more user-readable error to the client as is the case in Presage API. | |||
==== Can we make the timeouts longer? ==== | |||
Well, it's complicated. Currently the only timeouts at play are the VM-level and Web-container-level NGINX timeouts. So while those ''can'' be raised, it will be raised for ''every request to the API'', including requests that we'd prefer to time out at 60 seconds. If that's an acceptable tradeoff for your product, then the NGINX timeout can be raised ''for all GraphQL requests''. | |||
We could come up with a way to time out non-report GraphQL requests early, whether that's by creating a custom plugin for our GraphQL client (Houdini) or by adding something to the API servers that can know to time some requests out at 300s and some at 60s, but we haven't done anything like that yet. | |||
==== Why does it sometimes take a few minutes for a timed-out report preview to show in the "History" tab? ==== | |||
"Web Preview" jobs are only logged to the <code>reportqueue</code> table after the API receives a response from Crystal Server. If your preview timed out at 60 seconds, then the request from the web client to the API likely timed out, meaning the API is still waiting for a response from Crystal Server. Since the API is still waiting, it will either create the <code>reportqueue</code> row after the report finishes, or once the request from API -> Crystal Server times out, whichever happens first. And when the request from the client -> API times out, the API doesn't know about it - so it's possible for the <code>reportqueue</code> row to report no errors if the report finishes running before the request from API -> Crystal Server times out. Timeouts like this will probably come with the error <code>Failed to fetch: server returned invalid response with error 504: Gateway Time-out</code> in EEW/Presage Web, as that's what's returned from our GraphQL client when it hits an NGINX timeout. | |||
If the request from the API -> Crystal Server is the first to time out, the API will catch the timeout error and return a GraphQL error to the client. In this case, since the error was caught by the API, it will immediately log to <code>reportqueue</code>. | |||
=== How is Report Queue, the Python application, involved in this? === | |||
It's not. Crystal Server and Report Queue are completely separate applications. Crystal Server only generates PDF previews. Report Queue handles printing and emailing reports. Crystal Server is written in Node.js, Report Queue is written in Python. Their main similarity is that they both invoke Report Commander to generate the PDF file, and log to the <code>reportqueue</code> table. | |||
=== Why do Presage customers need set up manually? === | |||
Presage customers (generally) are on their own VM, and therefore database server. Therefore, they need their own entries in the Crystal Server config file. | |||
Theoretically SMB customers, since they're on the same server, could share a config, but that hasn't been explored as of 2/4/2026. | |||
=== Why do Enterprise customers need set up manually? === | |||
Enterprise customers are generally on their own VM or server. Additionally, EE customers might not want to use our central server, and might want to host their own. Therefore, they need their own entries in the Crystal Server config file, or their own Crystal Server instance entirely. | |||
=== Why don't Chromium customers need to be set up manually? === | |||
Since Chromium users are on one of three servers, (except for dev, demo, etc.) all Chromium instances can just use the config for their regional server | |||
== Common Errors (Table Mode) == | |||
This table will hold the answers to (probably) any error you will encounter running reports in Presage Web | This table will hold the answers to (probably) any error you will encounter running reports in Presage Web | ||
| Line 21: | Line 110: | ||
| Invalid Session. Try logging out and logging back in. || This means that the report server was not able to verify your session. Either your session has expired, or the Crystal Server is not configured for that database. The most likely cause of this is, if logging out and back in doesn't fix it, is that the (generally Presage) customer hasn't been set up on the Crystal Server, or some configuration has changed. || If the config for that customer is missing, then add it matching the template. If it is present, make sure that the Crystal Server and Chromium/Presage API are configured with the same DB URL. Otherwise, check the ODBC connection and DB credentials. Charles can check the logs to double check the URLs are good, as well as update the config file. Brian can then restart the Crystal Server service to load the updated configuration. | | Invalid Session. Try logging out and logging back in. || This means that the report server was not able to verify your session. Either your session has expired, or the Crystal Server is not configured for that database. The most likely cause of this is, if logging out and back in doesn't fix it, is that the (generally Presage) customer hasn't been set up on the Crystal Server, or some configuration has changed. || If the config for that customer is missing, then add it matching the template. If it is present, make sure that the Crystal Server and Chromium/Presage API are configured with the same DB URL. Otherwise, check the ODBC connection and DB credentials. Charles can check the logs to double check the URLs are good, as well as update the config file. Brian can then restart the Crystal Server service to load the updated configuration. | ||
|- | |- | ||
| rowspan=" | | rowspan="5" |Error running report. Double check the report parameters and try again. || This means that Report Commander did not receive the correct amount of parameters for the report. Often times, the report will run fine on desktop, because the Crystal SDK can "fill in the gaps" or ignore extra parameters, while the web Report Viewer cannot, and needs a row in reportparameter for every parameter. Check the <code>Report Viewer > History</code> tab for more error details || Generally, update the report and re-run adders, but '''See Below''' for more details, and check <code>Report Viewer > History</code> for more parameter and error details. If updating the report and adder doesn't fix it, it's possible that they are out of date and need fixed. | ||
|- | |- | ||
| '''"Invalid value for <parameter>"''' means Report Commander received an invalid value for the listed parameter. Usually this just means you forgot to fill a parameter out, but could be caused by by an outdated report / adders. || Make sure all parameters are filled out. | | '''"Invalid value for <parameter>"''' means Report Commander received an invalid value for the listed parameter. Usually this just means you forgot to fill a parameter out, but could be caused by by an outdated report / adders. || Make sure all parameters are filled out. | ||
| Line 28: | Line 117: | ||
|- | |- | ||
| '''"Missing parameter values"''' means that the report was not passed all expected parameters. Normally, this is because a parameter was added to the report, and the adders are out of date. || Re-run adders. | | '''"Missing parameter values"''' means that the report was not passed all expected parameters. Normally, this is because a parameter was added to the report, and the adders are out of date. || Re-run adders. | ||
|- | |||
| '''"The types of the parameter field and parameter field current values are not compatible"''' means that Crystal was passed a parameter value of the wrong type for that parameter. For example, a string instead of a number || Make sure ITrack is sending parameters of the type the report expects to receive | |||
|- | |- | ||
|| (I can't remember the error message) || Missing / invalid ODBC configuration. I think this presents as "could not connect to the database" or something to that effect. Sometimes it'll give you a "database vendor code" just like ITrack desktop. || Depending on the error code, Brian can make sure the ODBC connection is valid, and give Charles the name to check that the ODBC connection name in the Crystal Server config is correct. But some error codes like 1064 are unrelated to the odbc setup | || (I can't remember the error message) || Missing / invalid ODBC configuration. I think this presents as "could not connect to the database" or something to that effect. Sometimes it'll give you a "database vendor code" just like ITrack desktop. || Depending on the error code, Brian can make sure the ODBC connection is valid, and give Charles the name to check that the ODBC connection name in the Crystal Server config is correct. But some error codes like 1064 are unrelated to the odbc setup | ||
|- | |- | ||
|| Invalid Report || The Crystal Server failed to find the report with the specified name/type. || Make sure the report exists in the customer database with the given name and type, and a valid <code>report.fileid</code>. In Presage, there used to be a bug where running reports with a non-English language selected would fail with this error. | || "Invalid Report" or "No report found of type <type> and name <name>" || The Crystal Server failed to find the report with the specified name/type. || Make sure the report exists in the customer database with the given name and type, and a valid <code>report.fileid</code>. In Presage, there used to be a bug where running reports with a non-English language selected would fail with this error. | ||
|- | |- | ||
|| The file or directory is corrupted and unreadable || This would come up every so often because the D drive on Bunnahabhain was failing. It shouldn't happen anymore. || It shouldn't happen again, but if it does, delete the cached report file from <code>M:\report_cache</code> on Bunnahabhain. Maybe reupload the report if it persists after that. | || The file or directory is corrupted and unreadable || This would come up every so often because the D drive on Bunnahabhain was failing. It shouldn't happen anymore. || It shouldn't happen again, but if it does, delete the cached report file from <code>M:\report_cache</code> on Bunnahabhain. Maybe reupload the report if it persists after that. | ||
| Line 37: | Line 128: | ||
|| Database logon failed || ODBC could not connect to the database || Ask Brian (or maybe someone else from @Systems) to double check the ODBC connection on Bunnahabhain for that customer | || Database logon failed || ODBC could not connect to the database || Ask Brian (or maybe someone else from @Systems) to double check the ODBC connection on Bunnahabhain for that customer | ||
|- | |- | ||
|| <code>Database Vendor Code (code)</code> || There was some MySQL error. Look up the error code. || Might depend on the error code, but it's probably because of a bad query in the report. Reupload report. | || <code>Database Vendor Code (code)</code> || There was some MySQL error. Look up the error code. || Might depend on the error code, but it's probably because of a bad query in the report. Reupload report. If some parameters are missing or blank, there could have been an issue running a report parameter query, and omitting those parameters could have caused a syntax error (1064) | ||
|- | |- | ||
|| <code>Internal Server Error</code> || | || <code>Internal Server Error</code> || Either you're on a version of EEW that doesn't forward the error to the client properly, or you encountered an error that is not properly handled by Crystal Server || Check Report Viewer > History to see the actual error, or if that fails, the Crystal Server logs. | ||
|} | |} | ||
| Line 132: | Line 223: | ||
If they're self hosted, and don't want to use our Crystal Server, follow the steps under "Deployment", then set the above ENV variables to the proper values for their setup. | If they're self hosted, and don't want to use our Crystal Server, follow the steps under "Deployment", then set the above ENV variables to the proper values for their setup. | ||
=== Updating a Client to MySQL 8 === | |||
When a client's database is updated to MySQL 8, the MySQL connector 5.3 will no longer work. Update their ODBC to use the MySQL 8.0 Unicode driver, and turn off "Enable automatic reconnect" | |||
== Updating == | == Updating == | ||
Latest revision as of 15:45, 13 May 2026
This article applies to Presage Web and ITrack Chromium. The web Report Viewer will give a general error, error details are logged to the reportqueue table and can be viewed in the "History" (web) or "Print Queue" (desktop) tab of the Report Viewer screen.
Terms
- Crystal Server - the Node.JS application that uses Report Commander to generate the report PDF. Runs on Bunnahabhain. This application is not the same as Report Queue.
- Report Commander - command line application used to generate report PDFs by the Crystal Server (and Report Queue)
- Report Queue - python application that reads from reportqueue table to send emails and print to a printer. Report Queue is separate from Crystal Server, and the two systems do not interact.
- reportqueue - a table in the database that logs report runs.
- reportparameter - a table in the database that associates parameters to reports
FAQ
How does the web report viewer work?
Since we can't run crystal reports directly in the browser, we need to run them on a central server and send them back to the web browser. There are multiple servers involved in this process, which I'll outline below
- The report and parameter list are loaded from the application's API (Chromium, Presage API, EE API)
- The user selects a report, fills out parameters, and clicks "Preview"
- A request is sent to the application backend (Chromium, Presage API, EE API)
- Application backend sends a request to Crystal Server, running on Bunnahabhain, or a customer server if relevant. This requests includes details of the report to run, which database to run it on, and a valid session token for that database.
- Bunnahabhain takes this request, and attempts to validate the given session token in the given database. If this fails, such as if the token is invalid or it can't connect to the database, an "Invalid Session" error is thrown.
- After the session is validated, Crystal Server will download the report file from the customer's database, and run default parameter queries. The report is saved to the "cache directory" specified in the config, with the file's hash as the file name.
- Then, Crystal Server creates a command line string to run Report Commander for the given report and parameters
- Report Commander is then invoked to generate the PDF, connecting to the database with ODBC. The PDF is saved to a folder in the Crystal Server's "cache directory". If Report Commander throws an error, it is forwarded to the application API (Chromium, Presage API, EE API), which saves it to the
reportqueuetable and forwards that error to the client, where it is displayed. - If it succeeds, the report file is base64 encoded and sent back to the application API (Chromium, Presage API, EE API), along with the time it took to execute the report.
- The application API receives the request, saves the details to
reportqueue/reportqueueparameter, and returns the base64 encoded PDF to the client - The client receives the response from its backend, and displays the base64 encoded PDF in the browser using an
<object/>tag
How is that different from desktop?
ITrack desktop talks directly to the Crystal Reports SDK on the individual workstation, instead of sending report jobs to a central server (Bunnahabhain) running Crystal Server. Crystal Server then uses Report Commander to create the PDF.
What is handled by Crystal Server and what is handled by Report Queue?
Report Queue and Crystal Server are two separate systems that do not interact, so it's important to understand the boundaries between them.
Crystal Server generates PDFs that can be viewed in a web browser. Crystal Server only generates the PDF, but it's typically displayed in either the "Report Viewer" screen, or in the "Send Report" modal in the application that requested it.
Report Queue handles emailing and printing of reports. In the web, you can print/email using Report Queue by selecting "Printer" or "Email" in the "Send Report" modal.
Can Crystal Server (web report viewer) generate PDFs of different sizes?
Unfortunately not. Report PDFs created by Crystal Server are always letter size. Note that this only applies to report previews; if the customer has a Report Queue instance they can email or print a report of a different size that way.
Why can't web work the same way as desktop?
Chromium, Presage Web, and Enterprise Web run inside of a web browser, and can therefore be used on multiple operating systems without installing anything. Crystal Reports SDK is Windows-only and requires installation. Therefore, we need a central server to generate the pdf and send it back to the web browser (with some extra steps in between)
Why does this report run on desktop, but not on web?
As outlined above, web and desktop have entirely different stacks for running crystal reports. In short, web uses Report Commander instead of the Crystal SDK. I don't know exactly how the official Crystal SDK works, but it seems to be more tolerant to being passed extra parameters, or missing parameters. Report Commander is pickier so it will throw when you give it an extra parameter not found in the report, or if you are missing a required parameter value. As a result, basically every error in this Wiki article is web-exclusive.
Why aren't reports updated automatically in the web?
Report updates were historically done by ITrack/Presage desktop, and there is currently no system for automatically updating reports without using desktop. One is in progress, but as of 2/4/2026, it is not ready for primetime.
Why do I sometimes get "504 Gateway Timeout" when running a report in web?
As outlined above, there are multiple web servers involved in the process of generating a PDF from a Crystal Report in the web, and each one of them has their own server-level timeouts. The web server(s) connecting you to the application API (Chromium, Presage API, EE API) might time you out, and so might the web server connecting the application API to the Crystal Server.
The NGINX default timeout is 60 seconds, and it's expected that some reports will take longer than this. More on this later.
Presage Web has set its internal NGINX proxy_read_timeout for /graphql to 300s, meaning that any and all requests to the API will time out at 300s instead of the default of 60s. However, the VM-level NGINX also defaults proxy_read_timeout to 60s and if that's not raised, then the VM-level NGINX will time out before the Web-level NGINX hits its timeout.
Currently EE API uses the default proxy_read_timeout of 60s.
I do not know what timeouts are at play for Chromium since it uses a socket server instead of a GraphQL server like Presage Web and EEW do.
Requests to Crystal Server on Bunnahabhain currently time out at 4m, so provided that the web client -> API timeout is longer than that (such as 5m), the API can catch the timeout error and return a more user-readable error to the client as is the case in Presage API.
Can we make the timeouts longer?
Well, it's complicated. Currently the only timeouts at play are the VM-level and Web-container-level NGINX timeouts. So while those can be raised, it will be raised for every request to the API, including requests that we'd prefer to time out at 60 seconds. If that's an acceptable tradeoff for your product, then the NGINX timeout can be raised for all GraphQL requests.
We could come up with a way to time out non-report GraphQL requests early, whether that's by creating a custom plugin for our GraphQL client (Houdini) or by adding something to the API servers that can know to time some requests out at 300s and some at 60s, but we haven't done anything like that yet.
Why does it sometimes take a few minutes for a timed-out report preview to show in the "History" tab?
"Web Preview" jobs are only logged to the reportqueue table after the API receives a response from Crystal Server. If your preview timed out at 60 seconds, then the request from the web client to the API likely timed out, meaning the API is still waiting for a response from Crystal Server. Since the API is still waiting, it will either create the reportqueue row after the report finishes, or once the request from API -> Crystal Server times out, whichever happens first. And when the request from the client -> API times out, the API doesn't know about it - so it's possible for the reportqueue row to report no errors if the report finishes running before the request from API -> Crystal Server times out. Timeouts like this will probably come with the error Failed to fetch: server returned invalid response with error 504: Gateway Time-out in EEW/Presage Web, as that's what's returned from our GraphQL client when it hits an NGINX timeout.
If the request from the API -> Crystal Server is the first to time out, the API will catch the timeout error and return a GraphQL error to the client. In this case, since the error was caught by the API, it will immediately log to reportqueue.
How is Report Queue, the Python application, involved in this?
It's not. Crystal Server and Report Queue are completely separate applications. Crystal Server only generates PDF previews. Report Queue handles printing and emailing reports. Crystal Server is written in Node.js, Report Queue is written in Python. Their main similarity is that they both invoke Report Commander to generate the PDF file, and log to the reportqueue table.
Why do Presage customers need set up manually?
Presage customers (generally) are on their own VM, and therefore database server. Therefore, they need their own entries in the Crystal Server config file.
Theoretically SMB customers, since they're on the same server, could share a config, but that hasn't been explored as of 2/4/2026.
Why do Enterprise customers need set up manually?
Enterprise customers are generally on their own VM or server. Additionally, EE customers might not want to use our central server, and might want to host their own. Therefore, they need their own entries in the Crystal Server config file, or their own Crystal Server instance entirely.
Why don't Chromium customers need to be set up manually?
Since Chromium users are on one of three servers, (except for dev, demo, etc.) all Chromium instances can just use the config for their regional server
Common Errors (Table Mode)
This table will hold the answers to (probably) any error you will encounter running reports in Presage Web
| Error | Description | How to Fix |
|---|---|---|
| Invalid Session. Try logging out and logging back in. | This means that the report server was not able to verify your session. Either your session has expired, or the Crystal Server is not configured for that database. The most likely cause of this is, if logging out and back in doesn't fix it, is that the (generally Presage) customer hasn't been set up on the Crystal Server, or some configuration has changed. | If the config for that customer is missing, then add it matching the template. If it is present, make sure that the Crystal Server and Chromium/Presage API are configured with the same DB URL. Otherwise, check the ODBC connection and DB credentials. Charles can check the logs to double check the URLs are good, as well as update the config file. Brian can then restart the Crystal Server service to load the updated configuration. |
| Error running report. Double check the report parameters and try again. | This means that Report Commander did not receive the correct amount of parameters for the report. Often times, the report will run fine on desktop, because the Crystal SDK can "fill in the gaps" or ignore extra parameters, while the web Report Viewer cannot, and needs a row in reportparameter for every parameter. Check the Report Viewer > History tab for more error details |
Generally, update the report and re-run adders, but See Below for more details, and check Report Viewer > History for more parameter and error details. If updating the report and adder doesn't fix it, it's possible that they are out of date and need fixed.
|
| "Invalid value for <parameter>" means Report Commander received an invalid value for the listed parameter. Usually this just means you forgot to fill a parameter out, but could be caused by by an outdated report / adders. | Make sure all parameters are filled out. | |
| "Parameter not found in report: <parameter>" means that a parameter was passed to the report that the report doesn't expect. | If caused by an out-of-date report (more common), update the report. If caused by out-of-date adders, re-run adders. | |
| "Missing parameter values" means that the report was not passed all expected parameters. Normally, this is because a parameter was added to the report, and the adders are out of date. | Re-run adders. | |
| "The types of the parameter field and parameter field current values are not compatible" means that Crystal was passed a parameter value of the wrong type for that parameter. For example, a string instead of a number | Make sure ITrack is sending parameters of the type the report expects to receive | |
| (I can't remember the error message) | Missing / invalid ODBC configuration. I think this presents as "could not connect to the database" or something to that effect. Sometimes it'll give you a "database vendor code" just like ITrack desktop. | Depending on the error code, Brian can make sure the ODBC connection is valid, and give Charles the name to check that the ODBC connection name in the Crystal Server config is correct. But some error codes like 1064 are unrelated to the odbc setup |
| "Invalid Report" or "No report found of type <type> and name <name>" | The Crystal Server failed to find the report with the specified name/type. | Make sure the report exists in the customer database with the given name and type, and a valid report.fileid. In Presage, there used to be a bug where running reports with a non-English language selected would fail with this error.
|
| The file or directory is corrupted and unreadable | This would come up every so often because the D drive on Bunnahabhain was failing. It shouldn't happen anymore. | It shouldn't happen again, but if it does, delete the cached report file from M:\report_cache on Bunnahabhain. Maybe reupload the report if it persists after that.
|
| Database logon failed | ODBC could not connect to the database | Ask Brian (or maybe someone else from @Systems) to double check the ODBC connection on Bunnahabhain for that customer |
Database Vendor Code (code) |
There was some MySQL error. Look up the error code. | Might depend on the error code, but it's probably because of a bad query in the report. Reupload report. If some parameters are missing or blank, there could have been an issue running a report parameter query, and omitting those parameters could have caused a syntax error (1064) |
Internal Server Error |
Either you're on a version of EEW that doesn't forward the error to the client properly, or you encountered an error that is not properly handled by Crystal Server | Check Report Viewer > History to see the actual error, or if that fails, the Crystal Server logs. |
Other Errors
Error: WARNING: MYSQL_OPT_RECONNECT is deprecated and will be removed in a future version. - Disable "Auto Reconnect" on ODBC. Presents as "Unkown Error" or "Internal Server Error" in the UI
Logs
The log file lives at:
\\192.168.5.18\Node\crystal-reports-server\crystalserverservice.log
A normal log entry for a report job looks like this:
Connection created for 'hosteddb-southeast.isoftdata.com.373487'
args [
'-report="D:\\Node\\crystal-reports-server\\cache\\A95AC82D42C7A2A9AFF9F720DA5F3159.rpt"',
'-login!={server:reporting_hosted_southeast}{database:373487}',
'-exportfile="D:\\Node\\crystal-reports-server\\cache\\output\\default_invoice_2024-12-03T19-20-25.872Z.pdf"',
'-exportformat="PDF"',
'-namedparameters invoicenum="5150"'
]
Destroying connection for 'hosteddb-southeast.isoftdata.com.373487'
If you see a message like this, then the Crystal Server (not ODBC) failed to connect to the database, and there will probably be a logged request body right below it. The logged request body should have the db host sent from the application, which can be compared to the valid hosts in the config file
Destroying connection for 'iceriver.presageanalytics.com.UNKNOWN DATABASE'
The most common errors you'll see start like this and will show the command used to run Report Commander as well as a more-detailed error message in a mess of JSON.
ReportError: A Report Commander error has occurred
Configuration
This will go over how to configure a customer on the Crystal Server, not so much how to deploy and configure a new Crystal Server.
The config file lives at:
\\192.168.5.18\Node\crystal-reports-server\config.json
Generally, you just need to set the host, user, password, and odbc data sources for a new connection. However, host MUST be unique, and MUST match the ITrack/Presage server config, as that's what's used to look up the rest of the connection info. Most of the time you can just add another entry to the JSON, like so
{
"host": "HOST",
"user": "USER",
"password": "PASSWORD",
"odbcDataSource": "ODBC DATA SOURCE NAME"
}
In some cases you might also need to set the caPath, certPath, keyPath properties depending on the SSL config. See other configured hosts for examples.
After adding to the JSON, restart the CrystalServer service to apply any changes. See below for more product-specific details.
Chromium
Does not have to be configured per-customer. One config per VM. The users have more security and so they use more of the SSL options than other users
Presage Web/API
REPORT_SERVER_URI specifies the report server URI used by the server, and MYSQL_HOST specifies the DB host. EXTERNAL_DB_HOST will be sent to the Crystal Server instead of MYSQL_HOST, if specified. Either MYSQL_HOST or EXTERNAL_DB_HOST MUST match the host in the Crystal Server config file or it will not work!
SMB
Currently (12/04/2024), Culligan GI is the only Presage SMB customer, and was configured individually. Maybe in the future, Presage SMB will work like Chromium and just have one config per VM, but that's not currently the case.
Since the setup for SMB clients is slightly different, the MYSQL_HOST is an "internal" IP, but we need an external host that matches what the Crystal Server knows. To get around this, specify this ENV variable:EXTERNAL_DB_HOST: <customername>-database.presageanalytics.com. Make sure the URL matches the one in the Crystal Server config. Apparently, SMB DB URLs will always have -database in them since the SMB docker containers don't run on the same iron as MySQL.
As of 02/03/2025, there's also Bartlett, which had some issues setting it up related to SSL. Brian fixed it, I'm not sure what he did. I think they're also set up slightly differently than Culligan GI
Self-Hosted
If they're okay hitting our Crystal Server, we just need to make sure that their database can be reached on Bunnahabhain, then the setup is the same as a hosted yard.
If not, we'll have to deploy it to a Windows server they control, and set the REPORT_SERVER_URI ENV variable in the API to the proper URI. Presage API will have to be able to reach <The Server URL>/process_report in order to generate the reports
Enterprise Web/API
If we host the customer, we should just set them up on our Crystal Server. Follow the general steps for configuring them in the Crystal Server config.json, then set some ENV variables in Portainer:
REPORT_SERVER_URI: http://print.itrackchromium.comEXTERNAL_DB_HOST: example-url.itrackenterprise.com
WG, UT&W, & QBT are currently (07/08/25) the only EE customers with the web report viewer on, and they also had to have the caPath set in the crystal server config to the old/not-2024 ca cert. Not sure if that'll be true for other EE customers, but it was for them.
If they're self hosted, and don't want to use our Crystal Server, follow the steps under "Deployment", then set the above ENV variables to the proper values for their setup.
Updating a Client to MySQL 8
When a client's database is updated to MySQL 8, the MySQL connector 5.3 will no longer work. Update their ODBC to use the MySQL 8.0 Unicode driver, and turn off "Enable automatic reconnect"
Updating
Not 100% sure since it's been awhile, but I'm pretty sure the process is basically: 1. Build the Crystal Server to an exe again 2. Replace the old exe on BH 3. Restart CrystalServer service
Deployment
For 99% of customers, this section will not apply. But in the event that a self-hosted customer wants to host their own Crystal Server, this is probably how.
- Locate a Windows Server
- Install Report Commander on it
- Run CrystalServerSetup.exe from dl.isoftdata.com, I think this sets up the service to make it run in the background and on startup?
- Get the latest EXE or build a new one from https://github.com/ISoft-Data-Systems/crystal-reports-server and replace the old EXE from the installer
- Restart the CrystalServer service
- Make sure the service is reachable from wherever the Presage API is running
- At this point, they should be able to make a request to
serveruri/process_report and get a report back.
Misc / Notes
Housby has Crystal Server deployed to generate invoice PDFs for an ecommerce integration. They're using a version before we compiled it to an exe, so if they ever run into bugs or need an update it will be a little different