Difference between revisions of "Honeywell Scanner"
From ISoft Wiki
Jump to navigationJump to search
Line 18: | Line 18: | ||
Wedge as keys = empty input | Wedge as keys = empty input | ||
[[File:Flowchart_of_settings.jpg|800px|thumb| | [[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]] | ||
<br /> | |||
== Enterprise LX Honeywell config info == | |||
A global database setting "Scanner Mode (ambleMode,honeywell)" needs to be set to "honeywell" | |||
The current default is ambleMode which may change in the near future. | |||
The following query will let you check on the setting. Note: A user has to have logged into an lx app before the default settings are present. | |||
<syntaxhighlight lang="sql"> | |||
SELECT | |||
`globalsettingvalue`.`settingid` | |||
, `setting`.`location` | |||
, `setting`.`name` | |||
, `globalsettingvalue`.`value` | |||
, `setting`.`defaultvalue` | |||
, `setting`.`scope` | |||
, `setting`.`settingtype` | |||
, `value`=`defaultvalue` AS isdefault | |||
FROM | |||
`globalsettingvalue` | |||
INNER JOIN `setting` | |||
ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`) | |||
WHERE (`setting`.`name` = 'Scanner Mode (ambleMode,honeywell)'); | |||
</syntaxhighlight> |
Revision as of 15:53, 29 April 2021
Setting up a Honeywell Scanner
ScanPal EDA71 https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71
These are the screens you set through to set up the honeywell device
Settings -> Honeywell Settings -> Scan Settings -> Internal Scanner -> Default profile -> Data Processing Settings
Wedge = checked
Wedge Method = Keyboard
no Prefix
no Suffix
Wedge as keys = empty input
Enterprise LX Honeywell config info
A global database setting "Scanner Mode (ambleMode,honeywell)" needs to be set to "honeywell"
The current default is ambleMode which may change in the near future. The following query will let you check on the setting. Note: A user has to have logged into an lx app before the default settings are present.
SELECT
`globalsettingvalue`.`settingid`
, `setting`.`location`
, `setting`.`name`
, `globalsettingvalue`.`value`
, `setting`.`defaultvalue`
, `setting`.`scope`
, `setting`.`settingtype`
, `value`=`defaultvalue` AS isdefault
FROM
`globalsettingvalue`
INNER JOIN `setting`
ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)