Difference between revisions of "Honeywell Scanner"
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
== Compatibility Notes == | |||
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18 | |||
== Setting up a Honeywell Scanner == | == Setting up a Honeywell Scanner == | ||
ScanPal EDA71 | |||
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71 | |||
These are the screens you set through to set up the honeywell device | These are the screens you set through to set up the honeywell device | ||
Line 17: | Line 21: | ||
Wedge as keys = empty input | Wedge as keys = empty input | ||
[[File:Flowchart_of_settings.jpg]] | [[File:Flowchart_of_settings.jpg|800px|thumb|center|Honeywell Setting Flowchart]] | ||
<br /> | |||
== Enterprise LX Honeywell config info == | |||
A global database setting "Scanner Mode (ambleMode,honeywell)" needs to be set to "honeywell" | |||
The current default is ambleMode which may change in the near future. | |||
The following query will let you check on the setting. Note: A user has to have logged into an lx app before the default settings are present. | |||
<syntaxhighlight lang="sql"> | |||
SELECT | |||
`globalsettingvalue`.`settingid` | |||
, `setting`.`location` | |||
, `setting`.`name` | |||
, `globalsettingvalue`.`value` | |||
, `setting`.`defaultvalue` | |||
, `setting`.`scope` | |||
, `setting`.`settingtype` | |||
, `value`=`defaultvalue` AS isdefault | |||
FROM | |||
`globalsettingvalue` | |||
INNER JOIN `setting` | |||
ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`) | |||
WHERE (`setting`.`name` = 'Scanner Mode (ambleMode,honeywell)'); | |||
</syntaxhighlight> |
Latest revision as of 14:28, 18 May 2022
Compatibility Notes
Please update the Chrome browser on the Honeywell to Chrome v101 so that the Teardown app is sized correctly. It currently ships with Chrome v70. -JW 2022-05-18
Setting up a Honeywell Scanner
ScanPal EDA71 https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71
These are the screens you set through to set up the honeywell device
Settings -> Honeywell Settings -> Scan Settings -> Internal Scanner -> Default profile -> Data Processing Settings
Wedge = checked
Wedge Method = Keyboard
no Prefix
no Suffix
Wedge as keys = empty input
Enterprise LX Honeywell config info
A global database setting "Scanner Mode (ambleMode,honeywell)" needs to be set to "honeywell"
The current default is ambleMode which may change in the near future. The following query will let you check on the setting. Note: A user has to have logged into an lx app before the default settings are present.
SELECT
`globalsettingvalue`.`settingid`
, `setting`.`location`
, `setting`.`name`
, `globalsettingvalue`.`value`
, `setting`.`defaultvalue`
, `setting`.`scope`
, `setting`.`settingtype`
, `value`=`defaultvalue` AS isdefault
FROM
`globalsettingvalue`
INNER JOIN `setting`
ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)
WHERE (`setting`.`name` = 'Scanner Mode (ambleMode,honeywell)');