Setting up a Munbyn Scanner

This is for the MUNBYN IPDA081/IPDA086 Mobile Data Terminal: https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/
To set up:

Swipe up to see apps, then tap on "keyboardemulator".
On the "Function" page, make sure "Enable Scanner" is on.
Scanner1.png

On the "AppSettings" page, turn on "Release key off scan" (if it is not already enabled).
Scanner2.png

Then scroll down to "Process mode". Make sure it is set to "keyboard input". Under "End mark", none of the options should be checked.
Scanner3.png

Prefix/preamble and suffix/postamble for the device can be edited under "Data Format". If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.
Scanner4.png


NOTE on ENTERPRISE LX setup

enterpise lx default pre/postable preamble = "126" = "~" postamble = "13" = "Enter"